Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 20 de 37
Filter
1.
Chinese Journal of Rheumatology ; (12): 50-53, 2021.
Article in Chinese | WPRIM | ID: wpr-884371

ABSTRACT

Objective:To observe and analysis the clinical presentations and high resolution computed tomography (HRCT) features of patients with eosinophilic granulomatosis with polyangiitis (EGPA), and to provide support for clinical diagnosis and treatment decision.Methods:Clinical characteristics, relevant laboratory data, HRCT features, treatment and prognosis of 15 clinically confirmed EGPA patients were analyzed retrospectively. Statistical Program for Social Sciences (SPSS) 21.0 software was used for statistical analysis of the data.Results:Among the 15 patients, there were 8 males and 7 females, with a midian age of 48. Four cases (27%) were misdiagnosed as refractory asthma for the first time. The most common clinical manifestation was paranasal sinus inflammation in 14 cases (93%), followed by cough and wheeze in 13 cases (87%). In the laboratory examination, eosinophilia was found in 13 cases (87%) and ANCA positive in 5 cases (39%). The common chest HRCT signs were: fiber stripes in 13 cases (87%), patch ground glass opacities in 12 cases (80%), interlobular septal thickening in 10 cases (67%), and nodules in 9 cases (60%). The five-factor score (FFS) was used to score the patients, and FFS were 5(33%) with score 0 and 6(40%) with score1. Finally, 12 patients (80%) were discharged after remission.Conclusion:The EGPA has a low incidence and no spefic clinical manifestations and chest HRCT features, so it hasto be diagnosed by combination of paranasal sinus examination, electromyography and laboratory tests.

2.
Chinese Journal of Radiological Medicine and Protection ; (12): 11-15, 2019.
Article in Chinese | WPRIM | ID: wpr-734308

ABSTRACT

Objective To investigate the value of "one-stop" scanning of coronary and head and neck CTA in patients with normal body mass index (18 kg/m2 ≤ BMI ≤ 25 kg/m2) using low tube voltage (80 kVp).Methods In a retrospective analysis 80 patients with normal body mass index who had completed "one-stop" scanning of coronary and head and neck CTA were divided into A and B groups according to different scanning method,and 40 consecutive cases were selected in each group.Scanning parameters of group A and group B were tube voltage 80 kV,coronary CTA tube current 550 mA,head and neck CTA tube current 500 mA,and tube voltage 100 kV,coronary CTA tube current 450 mA,head and neck CTA tube current 400 mA separately.Subjective evaluation and objective evaluation were performed on the image quality of the two groups.CT values of coronary artery and head and neck CTA trunk branch vessel,contrast-to-noise ratio (CNR),image noise (SD) and effective dose between the two groups were compared.Results The image quality of both groups met the diagnostic requirements,and there was no statistically significant difference in subjective scores between two groups (P>0.05).The CT values of coronary arteries,the main branches of the head and neck (the common carotid artery,the internal carotid artery) and SD of head and neck CTA were significantly different between two groups (t=4.737,6.552,3.359,2.165,2.685,4.617,P<0.05).There was no statistically significant difference in SD of coronary CTA,CT values and CNR between head and neck vessels (middle cerebral artery) in group A and group B (P>0.05).The effective dose of coronary CTA in group A (1.16±0.20) mSy was reduced by 51.1% than that in group B (2.37±0.77) mSv.The effective dose of head and neck CTA in group A (0.37±0.03) mSv was reduced by 47.9% than that in group B (0.71 ± 0.17) mSv.Conclusions The image quality with subjective evaluation met the diagnostic requirements when using a low-tube voltage for "one-stop"scanning of coronary and head and neck CTA.The CNR values were basically consistent with the conventional scanning method,and the patient effective dose was reduced by about 50%.

3.
Journal of Biomedical Engineering ; (6): 870-876, 2018.
Article in Chinese | WPRIM | ID: wpr-773343

ABSTRACT

This paper aims to explore the feasibility of building a finite element model of left atrial diverticulum (LAD) using reverse engineering software based on computed tomography (CT) images. The study was based on a three-dimensional cardiac CT images of a atrial fibrillation patient with LAD. The left atrium and LAD anatomical features were accurately reproduced by using Geomagic Studio 12 and Mimics 15 reverse engineering software. In addition, one left atrial model with LAD and one without LAD were created with ANSYS finite element analysis software, and the validity of the two models were verified. The results show that it is feasible to establish the LAD finite element model based on cardiac three-dimensional CT images using reverse engineering software. The results of this paper will lay a theoretical foundation for further hemodynamic analysis of LAD.

4.
Chinese Journal of Radiology ; (12): 828-833, 2017.
Article in Chinese | WPRIM | ID: wpr-667044

ABSTRACT

Objective To investigate the diagnostic value and characteristics of breast lesion in digital breast tomosynthesis (DBT) in combination with synthesized two-dimensional (2D) images. Methods The prospective study enrolled women older than 18 years with clinically suspected breast lesion.One hundred and sixty seven patients with 177 lesions confirmed by biopsy or surgery were included. All the patients underwent full-field digital mammography(FFDM)and DBT examinations,and synthesized 2D images(V-preview)were reconstructed from DBT.The images of FFDM,V-preview images and DBT plus FFDM, V-preview images were analyzed. The breast imaging reporting and data system (BI-RADS) and characteristic for predicting benign and malignant lesion were also evaluated.The average glandular dose for a single mammographic view between FFDM and DBT was recorded.The Nonparametric Z test was used to compare the differences among four different mammographic images in BI-RADS.The differential diagnostic performance among different mammography was evaluated by ROC analysis.Independent t test was used to compare the average glandular dose between FFDM and DBT.Results One hundred three benign lesions and 74 malignant lesions were confirmed. Compared with FFDM images alone or plus DBT,the diagnostic values of V-preview images alone/or plus DBT were not significantly different(Z=0.187 and 0.226,P=0.851 and 0.821), but compared with V-preview, the diagnostic values of V-preview images plus DBT revealed significant difference(Z=3.546,P<0.01).The area under ROC for V-preview plus DBT were 0.899,and the sensitivity,specificity,and accuracy were 90.5%,89.3%,and 89.3%,separately.For the average glandular dose, there was no significant difference between FFDM (1.48 ± 0.52) mGy and DBT (1.56 ± 0.39) mGy examination(t=1.714,P=0.087).Conclusion Synthesized 2D images from DBT,which may eliminate the need for FFDM,in combination with DBT can improve the diagnostic efficiency.

5.
Journal of Biomedical Engineering ; (6): 940-944, 2015.
Article in Chinese | WPRIM | ID: wpr-359542

ABSTRACT

Right-sided cardiac valvular diseases have traditionally been considered less important than disease of mitral or aortic valve. However, severe tricuspid regurgitation could lead to right ventricle dysfunction and reduce patients' survival rate. In clinic setting, tricuspid valve disease should be paid more attention for patients with secondary tricuspid regurgitation caused by left-sided valvular surgery combined with irreversible annular dilatation increasing the risk of reoperation. In this review, we summarize the epidemiology, anatomy, pathology, diagnosis, ultrasound and cardiac magnetic resonance imaging findings in patients with tricuspid regurgitation.


Subject(s)
Humans , Echocardiography , Heart , Heart Valve Diseases , Diagnosis , Heart Ventricles , Diagnostic Imaging , Pathology , Magnetic Resonance Imaging
6.
Journal of Practical Radiology ; (12): 985-988, 2015.
Article in Chinese | WPRIM | ID: wpr-459596

ABSTRACT

Objective To evaluate the imaging features of ulcer-like projections (ULP)and penetrating atherosclerotic ulcers (PAU)of intramural hematoma(IMH)using dual-source CT (DSCT).Methods Retrospectively analysis of DSCT imaging data of 1 12 patients in our hospital was performed.The shape of hematoma and location of ULP and PAU were evaluated Stanford A and B IMH depicting on DSCT images.The maximum diameter of aorta,maximum thickness of hematoma,deepness of ulcer were com-pared between in patients of IMH with or without ULP and PAU.Results IMH manifested as circular or crescent high density on plain scan and without contrast enhancement on DSCT images in 1 12 cases.Among of them,68 cases(68/1 12,61%)of IMH had ULP or PAU,in which there were 21 cases(21/1 12,1 9%)with ULP and 47 cases(47/1 12,42%)with PAU,the mean maximum depth was (0.48±0.1 5)cm in ULP and (1.08±0.56)cm in PAU.There were 4 cases with ULP and 9 cases with PAU in 29 cases of Stanford type A,while 1 7 cases with ULP and 38 cases with PAU in 83 cases of Stanford type B.There were 14 cases with single ULP and 7 cases with multiple ULP in 21 patients with ULP,while there were 27 cases with single PAU and 20 cases with multiple PAU in 47 patients with PAU.There were 1 9 cases with both PAU and ULP.There was statistical significance that PAU occurred more likely in the descending aorta and distal aorta than that in ULP (P =0.028).Conclusion IMH patients are susceptible to ULP and PAU,DSCT can objectively evaluate CT features of ULP and PAU of IMH.

7.
Journal of Biomedical Engineering ; (6): 157-162, 2015.
Article in Chinese | WPRIM | ID: wpr-266708

ABSTRACT

In order to investigate the features of multidetector CT (MDCT) and magnetic resonance imaging (MRI) as well as the corresponding pathogic basis of solitary fibrous tumor (SFT) in the pelvis, we collected the clinical data of 13 patients with pathologically confirmed SFT in pelvis, and retrospectively reviewed the MDCT and MRI appearances. Of these enrolled patients, 6 received MDCT scans, 5 underwent MRI scans, and 2 underwent both MDCT and MRI examinations. Shown on the MDCT and MRI, the maximum diameters of the masses ranged from 4.0 to 25.2 cm (averaged 11.8 cm). Six masses were lobulated, and seven were round or oval. In addition, all masses were well-defined and displaced the adjacent structures to some degrees. On the computed tomography, all masses were of isodensity on unenhanced scans in general, among which five masses were demonstrated with hypodense areas. On the MRI T1-weighted image, all lesions were isointense, of which patchy hypointense areas were detected in 3 cases and radial hypointense areas were in 3 cases, and the other one was presented with homogenous intensity. On T2-weighted images, most of the lesions were mixed hyperintense, of which 3 cases were of heterogenous hyperintesity, radial hypointense areas were detected in 3 patients, and the other one was homogenously intense. On enhanced computed tomography and MRI, large supplying vessels were found in 4 cases; 12 cases showed moderate to conspicuous enhancement, and the other one was presented with mild homogenous enhancement. Of the patients with moderate to conspicuous enhancement, patchy areas of non-enhancement were detected in 7 cases, radial areas of progressive enhancement were detected in 3 cases, and the remained 2 cases showed homogenous enhancement. On pathology, the radial area presented as progressive enhancement was fibrosis. During the follow-ups after surgery, 2 patients had local recurrence and 1 had metastasis to liver. In conclusion, the SFT in the pelvis are commonly presented as a large solid, well-defined and hypervascular mass with necrosis or cystic changes at some extents together with the displacement of adjacent structures. The radial area with hypointensity on T2-weighted image and with progressive enhancement on enhanced magnetic resonance imaging is an important feature of SFT, which can be helpful for the diagnosis of this mass.


Subject(s)
Humans , Magnetic Resonance Imaging , Neoplasm Recurrence, Local , Pelvis , Pathology , Retrospective Studies , Solitary Fibrous Tumors , Diagnosis , Pathology , Tomography, X-Ray Computed
8.
Journal of Biomedical Engineering ; (6): 332-346, 2014.
Article in Chinese | WPRIM | ID: wpr-290758

ABSTRACT

This study aims to explore the inferior adhesion of the renal fascia (RF), and the inferior connectivity of the perirenal spaces (PS) with multidetector computed tomography (MDCT), and to investigate the diagnostic value of CT for showing this anatomy. From May to July 2012, eighty-two patients with acute pancreatitis presented in our hospital were enrolled into this study and underwent contrast-enhanced CT scans. All the image data were used to perform three dimensional reconstruction to show the inferior attachment of RF and the inferior connectivity of PS. The fusion of anterior renal fascia (ARF) and posterior renal fascia (PRF) next to the plane of iliac fossa were found on the left in 71.95% (59/82) cases, and on the right in 75.61% (62/82). In these cases, bilateral perirenal spaces, and anterior and posterior pararenal spaces were not found to be connected with each other. No fusion of ARF and PRF below the level of bilateral kidneys occurred on the left side in 28.05% (23/82) cases and on the right side in 24.39% (20/82). In these patients, the PS extended to the extraperitoneal space of the pelvic cavity and further to the inguinal region, and bilateral anterior and posterior pararenal spaces were not found to be connected with each other. Three-dimensional reconstruction on contrast-enhanced MDCT could be a valuable procedure for depicting inferior attachment of RF, and the inferior connectivity of PS.


Subject(s)
Adult , Humans , Abdominal Cavity , Contrast Media , Fascia , Image Processing, Computer-Assisted , Kidney , Multidetector Computed Tomography , Pancreatitis , Pathology , Pelvis , Tomography, X-Ray Computed
9.
Journal of Biomedical Engineering ; (6): 1117-1120, 2014.
Article in Chinese | WPRIM | ID: wpr-234447

ABSTRACT

This study aims to explore the clinical value of the computer-aided diagnosis (CAD) system for early detection of the pulmonary nodules on digital chest X-ray. A total of 100 cases of digital chest radiographs with pulmonary nodules of 5-20 mm diameter were selected from Pictures Archiving and Communication System (PACS) database in West China Hospital of Sichuan University were enrolled into trial group, and other 200 chest radiographs without pulmonary nodules as control group. All cases were confirmed by CT examination. Firstly, these cases were diagnosed by 5 different-seniority doctors without CAD, and after three months, these cases were re-diagnosed by the 5 doctors with CAD. Subsequently, the diagnostic results were analyzed by using SPSS statistical methods. The results showed that the sensitivity and specificity for detecting pulmonary nodules tended to be improved by using the CAD system, especially for specificity, but there was no significant difference before and after using CAD system.


Subject(s)
Humans , China , Diagnosis, Computer-Assisted , Early Diagnosis , Lung , Pathology , Radiographic Image Enhancement , Radiography, Thoracic , Thorax
10.
Chinese Journal of Radiology ; (12): 60-63, 2013.
Article in Chinese | WPRIM | ID: wpr-432935

ABSTRACT

Objective To determine the value of CT and MRI in the evaluation of littoral cell angioma(LCA) of spleen.Methods Two experienced radiologists retrospectively analyzed the clinical data,CT and MRI findings of 12 patients with pathology proven LCA of spleen.The patients underwent noncontrast enhanced CT scan,then enhanced CT (n =10) and MRI (n =3) were performed.Results The majority of patients (8/12) showed splenomegaly,with no obvious signs and symptoms of hypersplenism.The majority of patients (10/12) had the uncountable hypodense lesions,a few (2/12) had only a single lesion.None of the lesions contained any calcification or envelopement.On CT,the majority (7/10) of the lesions demonstrated well circumscribed border,with some lesions (3/10) demonstrating a less distinct border.The enhanced scan for low-density nodules demonstrated slow progressive enhancement.On MRI,all the LAC had well circumscribed borders,and demonstrated T1-hypointense and T2-hyperintense signalswith punctual hypointense in the T2 WI,and progressive enhancement on the post contrast images.DWI showed an increased diffusion of the lesions compared to the normal appearing splenic tissue.Conclusion CT and MR imaging of littoral cell angioma of spleen has certain imaging characteristics,those particular findings may potentially aid in the diagnosis.

11.
Journal of Biomedical Engineering ; (6): 89-94, 2013.
Article in Chinese | WPRIM | ID: wpr-234698

ABSTRACT

The purpose of this study was to explore the clinical value of ECG-gated dual-source CT angiography (DSCTA) in evaluating coarctation of aorta (CoA). 23 patients suspected with CoA underwent DSCTA and transthoracic echocardiography (TTE). Surgical results were taken as reference standard. 23 patients were diagnosed with CoA, 12 cases had focal stenosis of aorta, while 11 had tubular stenosis. 19 cases were associated with other cardiovascular malformations, including 5 cases of hypoplastic aortic arch, 5 of patent ductus arteriosus, 10 of ventricular septal defect, 2 of bicuspid aortic valve, 4 of collateral arteries, 2 of aberrant left subclavian artery and 2 of persistent left superior vena cava, respectively. The mean diameter of stenotic segment of aorta was (7.0 +/- 3.7) mm. In 9 patients with tubular CoA, the diameter and length of stenotic segment of aorta were (6.2 +/- 7. 3) mm and (29.2 +/- 5.9) mm, respectively. The accuracies of DSCTA and TTE in the diagnosis of CoA were 100% and 91.3% (P > 0.05), respectively. It is well concluded that ECG-gated DSCTA could accurately evaluate CoA and associated cardiovascular malformations, and provide detailed anatomic information before surgery.


Subject(s)
Adolescent , Adult , Child , Child, Preschool , Female , Humans , Infant , Male , Young Adult , Angiography , Methods , Aortic Coarctation , Diagnostic Imaging , General Surgery , Cardiac-Gated Imaging Techniques , Methods , Contrast Media , Echocardiography , Electrocardiography , Methods , Tomography, X-Ray Computed , Methods
12.
Journal of Biomedical Engineering ; (6): 272-311, 2013.
Article in Chinese | WPRIM | ID: wpr-234665

ABSTRACT

This paper is to compare dual-source computed tomography (DSCT) with trans-thoracic echocardiography (TTE) in the evaluation of anomalous pulmonary venous connection (APVC) to explore the advantages of DSCT. Thirty-one patients with APVC detected by DSCT were enrolled in this study. In this cohort, 16 patients underwent echocardiography followed by operative treatments; and among the remained 15 patients who did not received surgical treatment, echocardiography was performed in 10 patients. The numbers and drainage sites of anomalous pulmonary veins, and accompanied defects on DSCT and TTE were retrospectively analyzed. In terms of diagnosis of the numbers and the drainage sites of anomalous pulmonary veins, the accuracy of DSCT was 98% (49/50) and 93.8% (15/16), while the accuracy of echocardiography was 80% (40/50) and 56.3% (9/16), respectively. There were statistical differences between the two modalities (P < 0.05). Although the detection rates of accompanied defects were 89.1% (41/46) and 78.3% (36/46) for DSCT and echocardiography, respectively, no statistically significant difference was found between the two modalities (P > 0.05). The 15 patients without receiving surgical treatments were partial APVC confirmed by DSCT, but APVC was found in 40% (4/10) patients by echocardiography. In conclusion, DSCT could be superior to evaluating APVC in comparison with echocardiography, and should be recommended as an important procedure for preoperative assessment of the anomaly in patients with APVC.


Subject(s)
Adolescent , Adult , Aged , Child , Child, Preschool , Female , Humans , Infant , Male , Middle Aged , Young Adult , Echocardiography , Evaluation Studies as Topic , Radiographic Image Interpretation, Computer-Assisted , Retrospective Studies , Scimitar Syndrome , Diagnostic Imaging , Tomography, X-Ray Computed , Methods
13.
Journal of Biomedical Engineering ; (6): 508-512, 2013.
Article in Chinese | WPRIM | ID: wpr-234621

ABSTRACT

This paper was aimed to explore the features of single ventricle with dual source computed tomography (DSCT) and the value of the modality in diagnosis of the single ventricle disease. Dual-source computed tomography imaging of 14 cases of single ventricle compared with the results of surgery and cardiac catheter were retrospectively analyzed. Firstly, 14 cases were classified into three types according to Anderson classification method, including 7 cases(50. 0%) left ventricular type, 3 cases(21. 4%) right ventricular type and 4 cases (28. 6%) undecided ventricular type. Secondly, in accompanying malformation respect, pulmonary stenosis, bilateral superior vena cava, atrial septal defect (ASD) and common atrioventricular valve were presented frequently. Thirdly, affiliated cardiac chamber of left ventricular type were mostly in front of the major cardiac chamber (5 cases,71. 4%), while affiliated cardiac chamber of right ventricular type were behind of the major cardiac chamber totally. Fourthly, more than half of aortas and pulmonary arteries stemming from common cardiac chamber can be seen (8 cases, 57. 1%). Meanwhile the aorta valves were more on the right of pulmonary valve (9 cases, 64. 3%). The classification of 10 cases of single ventricle was compared with the results of surgery, and the coincidence rate is 100%. DSCT can diagnose the single ventricle disease accurately. The aorta, pulmonary artery and coronary artery can be displayed completely and simultaneously as well.


Subject(s)
Adolescent , Child , Child, Preschool , Female , Humans , Infant , Male , Heart Ventricles , Congenital Abnormalities , Diagnostic Imaging , Radiography, Dual-Energy Scanned Projection , Methods , Retrospective Studies , Tomography, X-Ray Computed , Methods
14.
Journal of Biomedical Engineering ; (6): 1219-1223, 2013.
Article in Chinese | WPRIM | ID: wpr-259736

ABSTRACT

We studied the actions of diffusion weighted imaging (DWI) and dynamic contrast enhanced (DCE) magnetic resonance imaging (MRI) in differentiating breast tumors. From January 2010 to February 2012, we retrospectively analyzed data of 95 cases with breast tumor pathologically confirmed from DWI and DCE-MRI. We compared the ADC value, time-intensity curve (TIC) and DCE-MRI parameters between breast tumors, and calculated the sensitivity and specificity for differentiating breast tumors. The results were as follows: (1) On DWI, mean ADC value of malignant tumor was lower than that of benign tumor (P < 0.05). For differentiating breast malignant tumors from benign neoplasm, a cut-off ADC value of 1.2 x 10(-3) mm2/s achieved a sensitivity of 74.1% and specificity of 70.3%. (2) On DCE-MRI, early enhancement ratio (EER) value of malignant tumor was higher than that of benign tumor whereas value of time to peak (Tpeak) and maximal enhancement ratio (SImax) were lower than that of benign tumor (all P < 0.05). As for TIC, type II and III were more frequently seen in malignant tumor than in benign tumor whereas type I was more common in benign tumor than in malignant tumor (all P < 0.05). For differentiating breast malignant tumors from benign neoplasm, DCE-MRI obtained a sensitivity of 89.7% and specificity of 70.3%. (3) For differentiating breast malignant tumors from benign neoplasm, ADC value together with TIC obtained a sensitivity of 79.3% and specificity of 78.4%. Malignant or benign breast tumors could have their own unique characteristics on DWI and DCE-MRI. These characteristics might be helpful for differentiating these tumors.


Subject(s)
Female , Humans , Breast Neoplasms , Classification , Diagnosis , Diagnosis, Differential , Diffusion Magnetic Resonance Imaging , Magnetic Resonance Imaging , Retrospective Studies , Sensitivity and Specificity
15.
Journal of Biomedical Engineering ; (6): 70-96, 2012.
Article in Chinese | WPRIM | ID: wpr-274901

ABSTRACT

To evaluated the multi-detector CT (MDCT) and magnetic resonance imaging (MRI) features of localized Castleman's disease (CD), we retrospectively analyzed the clinical data, MDCT and MRI findings of 13 patients with CD proved pathologically. All patients underwent plain MDCT scan, 11 underwent enhanced CT, and 2 MRI. 14 lesions were detected in the 13 patients, and all of them were hyaline-vascular type (HV-CD) histopathologically. On plain MDCT scans, all lesions were homogeneously attenuated soft tissue mass; intra-tumoral calcification with punctate and "arborizing" patterns was detected in the center of 2 lesions each. Of the patients with enhanced MDCT, all lesions showed obvious enhancement homogeneously except two lesions with central stellate and 1 lesion with dotted low attenuation. Tortuous vessels could be revealed at the periphery of 8 lesions. Of the 2 patients with MRI, the lesions showed slightly hyper-intensity on T1WI, hyper-intensity on T2WI and marked homogenous enhancement. In addition, one of them showed signal void appearance in the center on unenhanced MRI and large supplying artery with tortuous vessels at the periphery on enhanced MRI. In a word, Localized HV-CD usually demonstrated as soft tissue mass with obvious enhancement on MDCT and MRI. Central stellate area of low attenuation and calcification with punctate or "arborizing" pattern may also be present.


Subject(s)
Adolescent , Adult , Female , Humans , Male , Middle Aged , Young Adult , Castleman Disease , Diagnosis , Diagnostic Imaging , Pathology , Image Enhancement , Magnetic Resonance Imaging , Multidetector Computed Tomography , Retrospective Studies
16.
Journal of Biomedical Engineering ; (6): 658-662, 2012.
Article in Chinese | WPRIM | ID: wpr-271714

ABSTRACT

The present paper is aimed to observe the lateral attachment of the renal fascia (RF) in vivo with multidetector computed tomography (MDCT) scanning, and to discuss its diagnostic value. 121 healthy adults were adopted into this experiment. All images were obtained with MDCT and double phase enhancement scanning. Then we observed the lateral attachment of RF. In addition, we mad a fresh body specimen as anatomical basis. The study found that above the renal hilar plane (RHP), the anterior renal fascia laterally fused with the peritoneum of the liver on the right and the peritoneum of the spleen on the left,and the posterior renal fascia fused with the subdiaphragmatic fascia. The lateral attachment of the RF at the RHP and the lower renal pole(LRP)is divided into three types. The RF in Type I is about 47.9% (58/121) at the left RHP, while about 33.9% (41/121) at the right RHP. At the LRP of the kidney is about 55.3% (67/121) on the left, and about 42.1% (51/121) on the right. The RF in Type I is about 38.8% (47/121) on the left side at the RHP, about 26.4% (32/121) on the right side. At the LRP, left side about 27.3% (33/121), right side about 13.3%(16/121). The RF in Type III at the RHP is 13.3% (16/121) on the left side, and on the right side is about 39.7% (48/121). At the LRP, it is about 17.4% (21/121) on the left side, and about 44.6% (54/121) on the right side. MDCT can display the lateral attachment of the RF better as well as the outside connection of the retroperitoneal space.


Subject(s)
Adult , Aged , Aged, 80 and over , Female , Humans , Male , Middle Aged , Young Adult , Fascia , Diagnostic Imaging , Kidney , Diagnostic Imaging , Multidetector Computed Tomography , Retroperitoneal Space , Diagnostic Imaging
17.
Journal of Biomedical Engineering ; (6): 862-866, 2012.
Article in Chinese | WPRIM | ID: wpr-246543

ABSTRACT

The purpose of this study was to determine the morphological and dynamic features of normal pulmonary valve by using dual-source CT. Thirty patients who underwent dual-source CT angiography with right ventricular outflow tract well-opacified were enrolled. Ten phases of images were reconstructed at 10% R-R interval, and pulmonary valve area and pulmonary annular diameter were measured on all 10 phases. As the pulmonary valve opened, its orifice appeared as oval or proximate triangle. As the pulmonary valve closed, it appeared as "Y-shape". Pulmonary valve opened from 10% to 30% phases, with maximum pulmonary valve area of (4.74 +/- 0.69) cm2 in 10% phase. Pulmonary valve closed from 40% to 90% phases. Pulmonary annular diameter varied with cardiac cycle, with maximum pulmonary annular diameter of (2.36 +/- 0.24) cm in 0% phase and minimum pulmonary annular diameter of (1.82 +/- 0.32) cm in 40% phase (P < 0.001). The proximal phase for assessing pulmonary valve was 70% phase. Dual-source CT may evaluate the morphological and dynamic features of normal pulmonary valve.


Subject(s)
Adult , Female , Humans , Male , Middle Aged , Iohexol , Pulmonary Valve , Diagnostic Imaging , Physiology , Tomography, Spiral Computed , Methods
18.
Journal of Biomedical Engineering ; (6): 1084-1088, 2012.
Article in Chinese | WPRIM | ID: wpr-246502

ABSTRACT

The purpose of this study is to explore the clinical value of ECG-gated dual-source CT angiography (DSCTA) in evaluating pulmonary atresia with ventricular septal defect (PA-VSD). We carried out retrospective analysis on 20 patients who had DSCTA with PA-VSD. The emphasis of the work was on analyzing the types of PA-VSD, pulmonary artery development, major aorto-pulmonary artery collateral arteries (MAPCAs) and associated intra- and extra-cardiac malformations. In the 20 cases of PA-VSD, there were 6 cases of type A , 13 cases of type B, and 1 case of type C. 12 cases of the patients had patent ductus arteriosus (PDA). The pulmonary blood flow was mainly supplied by PDA in 6 cases and by MAPCAs in the rest of 14 cases. The diameter of MAPCAs was (7.2 +/- 3.4) mm (range, 2.0-14.3 mm). The experiments proved that ECG-gated DSCTA was a convenient and noninvasive cardiovascular imaging method, and it could accurately evaluate the types of PA-VSD, pulmonary artery development, MAPCAs, and it could also provide detailed anatomic information before surgery.


Subject(s)
Adolescent , Adult , Child , Child, Preschool , Female , Humans , Infant , Male , Young Adult , Abnormalities, Multiple , Diagnostic Imaging , Angiography , Methods , Cardiac-Gated Imaging Techniques , Methods , Contrast Media , Heart Septal Defects, Ventricular , Diagnostic Imaging , Pulmonary Atresia , Diagnostic Imaging , Retrospective Studies , Tomography, X-Ray Computed , Methods
19.
Journal of Practical Radiology ; (12): 168-171, 2010.
Article in Chinese | WPRIM | ID: wpr-403382

ABSTRACT

Objective To investigate the multi-slice spiral computed tomography (MSCT) features of crush maxillofacial frac-tures in the massive Wenchuan earthquake. Methods MSCT data of 85 patients with crush maxillofacial fractures caused by earth-quake were retrospectively analyzed. The anatomic distribution of fractures was evaluated. Results In 85 patients, single bone frac-tures (59 patients) were more common than multiple bone fractures (26 patients) (P<0.05). The fractures involved isolated mid-face, isolated mandible, and both were found in 49 patients (57.6%), 24(28.2%), and 12(14.2%), respectively. Midface frac-tures were most frequent (P<0.05). The fractures of condyle, posterolateral and anterior wall of maxillary sinus, zygomatic arch and lateral orbital wall accounted for 47.1%(24/51) ,41.5%(22/53) , 37.7%(20/53),71.9% (23/32) and 63.2%(24/38) of the total fractures of the corresponding maxillofacial bones. Conclusion Isolated bone fracture and midface factures are the main fea-tures of crush maxillofacial fractures resulted from the massive earthquake. MSCT and three-dimensional reconstruction images can demonstrate maxillofacial fractures well.

20.
Chinese Journal of Primary Medicine and Pharmacy ; (12): 1952-1953,插图2, 2009.
Article in Chinese | WPRIM | ID: wpr-537783

ABSTRACT

Objective To evaluate the value of 16-slice spiral computed tomography(SCT)in diagnosing acute aortic syndrome.Methods Thirty-four cases with acute aortic syndrome underwent 16-slice SCT,performed with unenhanced,contrast-enhanced scanning of bolus tracking and three-dimensional reconstruction.The CT findings of these cases were analysed.Results Twenty-three of them were confirmed Aortic Dessection(AD),the true and false lumen,intimal flap,extent involved and complications of which were all revealed.Six cases were confirmed intramural aortic hematoma(IMH),with features of ring or crescent-shaped non-enhanced thickening wall around the aorta.Five cases were confirmed penetrating atherosclerotic ulcer(PAU),with features of niche sign outstanding the lumen of the aorta.Conclusion Acute aortic syndrome can he diagnosed exactly and completely by 16-slice SCT,which can provide valuable information to select therapeutic methods.

SELECTION OF CITATIONS
SEARCH DETAIL